PTW Innovation Milestones - A Selection


1922


Klicken um Bild zu vergrößern

PTW-Freiburg is established as one of the first dosimetry companies in the world, after W.C. Röntgen had discovered the X-rays, producing the revolutionary Hammer dosemeter to solve the problem of quantifying the radiation load given to patients.

1929


Introduction of the first commercial water phantoms and waterproof chambers by PTW. Although the ionization chamber had to be moved from point to point manually such a quality-built phantom meant a considerable improvement for the first hospital physicists.

1959


Klicken um Bild zu vergrößern

DIAMENTOR, the first diagnostic patient dosemeter for dose area product (DAP) measurements is introduced, enabling the X-ray operator to supervise the exposure during X-ray examinations for radiation protection of patients, today a must in X-ray diagnostics.

1976


Klicken um Bild zu vergrößern

Introduction of the world famous and wide spread MARKUS electron chamber with very thin entrance window and small volume for precison dosimetry of high-energy electron beams in radiotherapy.

1992


Klicken um Bild zu vergrößern

UNIDOS, the first top-of-the-line radiotherapy dosemeter with microprocessor control and 1fA resolution is introduced, a bench mark in medical physics.

1993


Klicken um Bild zu vergrößern

Another innovation in diagnostic patient dosimetry: The first DIAMENTOR-KDK system with combined ionization chamber for simultaneous patient radiation protection measurement of DAP and dose during X-ray examinations according to international protocols is introduced.

1996


Klicken um Bild zu vergrößern

The Linear Chamber Array LA48 is introduced, the first and still unique detector array, based on liquid ionization chambers and used for comfortable and fast analyses of dynamic therapy fields.

1997


Klicken um Bild zu vergrößern

The first extremely small-volume PINPOINT ionization chamber for IMRT and stereotactic beam dosimetry and verification is introduced, overcoming the drawbacks of diode detectors.

2001


Klicken um Bild zu vergrößern

VeriSoft, the first and most comprehensive software package for comfortable IMRT beam verification, combinable with all relevant therapy planning systems, is introduced.

2002


Klicken um Bild zu vergrößern

DIAVOLT, the first non-invasive kV measuring device for the measurement of ppv (practical peak voltage), the new and very practical kV parameter for quality control of X-ray units, is introduced.

2002


Klicken um Bild zu vergrößern

From single point measurement to planar dosimetry: The revolutionary planar ionization chamber matrix 2D-ARRAY for two-dimensional, real-time and high precision IMRT dosimetry is introduced.

2006


Klicken um Bild zu vergrößern

Another unique system is introduced: The in-vivo system DAVID, based on the new again revolutionary multi-wire ion chamber technology, and used for the verification of IMRT beams during patient treatment.